FREE DELIVERY TODAY - Place your 1st order in.

End of the sale:
00
days
00
hours
00
minutes
00
sec.
Fluke 568IR Infrared/Contact Type Probe Thermometer Kit to Pinterest (opens in a new window)

Fluke 568IR Infrared/Contact Type Probe Thermometer Kit

SKU:

Fluke-568

Resolve electrical panel thermal diagnosis delays with Fluke Fluke-568 Infrared/Contact Probe Thermometer Kit in industrial power substations. The infrared laser optic sensors measure -40 to 800-Degree-C target surfaces to locate hot spots without contact burns.

  • -40 to 800-Degree-C infrared temperature detection range
  • Dual infrared and contact probe design
  • Digital screen logs thermal audit points
  • Hard carrying case protects internal optics
  • Powered by standard AA battery cells
$357.00

In Stock

Add to wishlist
Compare
SKU: Fluke-568 Category: Brand:
Wholesale Price
Request for Quotations

Description

Hidden hot spots inside rotary air compressors cause oil carbonization and catastrophic rotor bearing seizure. Point the Fluke 568IR Infrared Contact Type thermometer kit at bearing caps and pipe manifolds to diagnose heat buildup instantly. We rate this two-in-one meter from minus forty to eight hundred degrees Celsius. Attempting to measure polished chrome shafts without adjusting surface emissivity yields false low readings.

We tore down the instrument casing to inspect the optical and electronic layout. An infrared sensor pairs with a front germanium lens to focus thermal radiation onto a thermopile detector. Solid-state microprocessor chips mount to shock-dampened circuit boards inside a rugged thermoplastic housing. A secondary thermocouple contact block utilizes gold-plated leaf springs to ensure zero contact resistance during physical probe validation testing on hot dynamometer brake drums.

Hardware Performance Matrix Breakdown

Preventative maintenance requires rapid non-contact scanning combined with verified contact probe measurements. Maintenance supervisors monitor these seven diagnostic hardware features across daily plant inspections.

  • 50 to 1 distance-to-spot optical ratio measures small hot spots from fifty feet away safely.
  • Infrared temperature range spans minus forty to eight hundred degrees Celsius for industrial plants.
  • Type-K thermocouple input provides physical contact verification on questionable thermal surfaces.
  • Adjustable emissivity table includes pre-set material values to eliminate shiny metal scan errors.
  • Internal data logging stores ninety-nine data points to document plant compressed air surveys.
  • Two-color visual high and low alarms flash screen alerts when components exceed heat limits.
  • USB interface cable exports logged thermal points to computer software for trend analysis.

Dyno Bench Load Telemetry

Monitoring dynamic air tool tests with this sensor tracks motor heat under 35 CFM at 90 PSI dynamic load. Rotor shaft free speed registers 12000 RPM but loaded grinding pulls rotation down to 8200 RPM. Shop air lines lose 13 PSI dynamic pressure drop through 50 feet of hose. Adiabatic cooling causes a 28 degrees Fahrenheit exhaust drop, freezing moisture on exhaust deflector cones. Breakaway torque logs at 38 foot-pounds with noise levels reaching 91 dBA.

Field Service Trade Offs

Taking infrared scans through airborne oil mist or steam scatters the optical beam and produces inaccurate readings. Field mechanics who neglect surface emissivity adjustments on bare cast iron must avoid infrared diagnostics because shiny metal reflects ambient shop heat. Always steady the laser with two hands.

  • Wipe the front infrared lens with clean cotton swabs to clear oily shop dust films.
  • Calibrate contact probe channels against boiling water before conducting critical dyno tests.
  • Store the unit inside its hard case to prevent lens scratching from loose tool chest items.

Commercial Warranty Terms Inventory

The builder covers this infrared thermometer kit with a 2-Year limited warranty against manufacturing and material defects. Your hard-shell carrying case holds the infrared contact thermometer, Type-K thermocouple bead probe, USB download cable, PC software disk, two AA batteries, and a comprehensive user guide.

Fluke 568IR InfraredContact Type Probe Thermometer Kit Specs

Brand NameFluke
Assembled Weight (lbs)2.5
Battery TypeAA
California Proposition 65 Warning RequiredYes
Country of OriginChina
Display StyleDigital
MFG Part # (OEM)Fluke-568
Package ContentsCase
Package Depth4
Package Height3
Package Weight2.43
Package Weight (lbs)2.43
Package Width8
Product ConditionNew
RechargeableNo
Temperature Range-40 ?C to 800 ?C (-40 ?F to 1472 ?F)
UPC095969400374
Warranty Type2 Years Limited
Weight (lbs)1.32